Overload protection |
105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover |
Over voltage protection |
15.75 ~ 18.75V, 31.5 ~ 37.5V, 63 ~ 75V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, recovers automatically after temperature goes down |
Withstand voltage |
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC (0.5KVAC for 12V) |
Working temperature |
-30 ~ +70℃(Refer to "Derating Curve") |
Safety standards |
UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV EN62368-1, EAC TP TC 004 approved |
EMC Conduction & Radiation |
Parameter |
Standard |
Test Level / Note |
EMC Conduction & Radiation |
EN55024, EN61000-6-2 |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
Surge |
EN61000-4-5 |
Level 4, 2KV/Line-Line 4KV/Line-Earth |
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
162.2K hrs min. Telcordia SR-332 (Bellcore) ; 39.3K hrs min. MIL-HDBK-217F (25℃) |
Packing |
1.87Kg; 6pcs/12.2Kg/1.16CUFT |