E-Star Power Supply Mail to Us power supply products
| AC DC Power Supply | | Medical Power Supply | | DC DC Power Supply | | AC POWER CORD |- | Contact Us | - | Home |
 
AC DC Power Supply
> Led Driver Power Supply
> 75W
>XLG-75
 
 
 
 
 
AC DC Power Supply > Led Lighting Control Driver Power Supply > 75W > XLG-75
Power Supply XLG-75
Features : * Wide input range 100~305VAC(Class I)
* Full power output at 70~100% Constant power mode operation
* Metal case with IP67, suitable for outdoor application
* Class 2 power unit (excep for L type)
* Surge protection with 6KV/4KV (10KV/6KV optional)
* 3 in 1 dimming function (Dim to off and Isolation design)
* India (EESL) version with Input Ovet Voltage Protection can survive input voltage stress of 440 Vac for 48 hours
* Protection functions: OVP/ SCP/ OCP/ OTP
* Life time>50,000 hrs. and 5 years warranty
Model No. :

XLG-75

AC input voltage range 100 ~ 305VAC 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
Power Factor (Typ.)
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
AC Inrush Current (Typ.) COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
Leakage Current <0.75mA / 277VAC
Over Current protection

95 ~ 108%
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed

Over Voltage protection 13.5 ~ 19V, 26 ~ 36V(XLG-100[]-12-[],XLG-100[]-24-[])
Shut down output voltage, re-power on to recover
320~370V(XLG-100[]-L-[],XLG-100[]-H-[])
(Shut down output voltage shen the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
can survive input voltage stress of 440 Vac for 48 hours
Over Temperature Shut down output voltage, re-power on to recover
Working temperature Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Safety standards UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14;
EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-100I type only); IP67 approved
Withstand voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
EMC EMISSION Parameter Standard Test Level/Note
Conducted EN55015(CISPR15) ,GB/T17743 -----
Radiated EN55015(CISPR15) ,GB/T17743 -----
Harmonic Current EN61000-3-2 , GB/T17625.1 Class C @load≥50%
Voltage Flicker EN61000-3-3 -----
EMC IMMUNITY EN61547
Parameter Standard Test Level/Note
ESD EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated EN61000-4-3 Level 3
EFT/Burst EN61000-4-4 Level 3
Surge EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Conducted EN61000-4-6 Level 3
Magnetic Field EN61000-4-8 Level 4
Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF 1232.28K hrs min. Telcordia SR-332 (Bellcore) ; 376.37Khrs min. MIL-HDBK-217F (25℃)
Packing 0.58Kg;24pcs /15Kg /0.85CUFT
Dimension 140*63*32mm (L*W*H)
P/No. Output Voltage Renge
RATED CURRENT Voltage Tol.
Effi.
XLG-75[]-12-[] 12V 5A ±3.0% 89%
XLG-75[]-24-[] 24V 3.1A ±2.0% 90%
  CONSTANT CURRENT REGION   CURRENT TOLERANCE  
XLG-75[]-L-[] 50~107V 700mA ±5% 91%
XLG-75[]-H-[] 27 ~ 56V 1400mA ±5% 90%
 