E-Star Power Supply Mail to Us power supply products
| AC DC Power Supply | | Medical Power Supply | | DC DC Power Supply | | AC POWER CORD |- | Contact Us | - | Home |
 
AC DC Power Supply
> Led Driver Power Supply
> 100W
>XLG-100
 
 
 
 
 
AC DC Power Supply > Led Lighting Control Driver Power Supply > 100W > XLG-100
Power Supply XLG-100
Features : * Wide input range 100~305VAC(Class I)
* Full power output at 70~100% Constant power mode operation
* Metal case with IP67, suitable for outdoor application
* LVLE (H type) Class 2 (24V) power unit
* Surge protection with 6KV/4KV (10KV/6KV optional)
* 3 in 1 dimming function (Dim to off and Isolation design)
* India (EESL) version with Input Ovet Voltage Protection can survive input voltage stress of 440 Vac for 48 hours
* Protection functions: OVP/ SCP/ OCP/ OTP
* Life time>50,000 hrs. and 5 years warranty
Model No. :

XLG-75

AC input voltage range 100 ~ 305VAC 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
Power Factor (Typ.)
PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
AC Inrush Current (Typ.) COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
Leakage Current <0.75mA / 277VAC
Over Current protection

95 ~ 108%
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed

Over Voltage protection 13.5 ~ 18V, 27 ~ 34V(XLG-100[]-12-[],XLG-100[]-24-[])
160 ~ 220V, 66 ~ 90V(XLG-100[]-L-[],XLG-100[]-H-[])
Shut down output voltage, re-power on to recover
Over Temperature Shut down output voltage, re-power on to recover
Working temperature Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Safety standards UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1,GB19510.14;
EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-100I type only); IP67 approved
Withstand voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
EMC EMISSION Parameter Standard Test Level/Note
Conducted EN55015(CISPR15) ,GB/T17743 -----
Radiated EN55015(CISPR15) ,GB/T17743 -----
Harmonic Current EN61000-3-2 , GB/T17625.1 Class C @load≥50%
Voltage Flicker EN61000-3-3 -----
EMC IMMUNITY EN61547
Parameter Standard Test Level/Note
ESD EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated EN61000-4-3 Level 3
EFT/Burst EN61000-4-4 Level 3
Surge EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Conducted EN61000-4-6 Level 3
Magnetic Field EN61000-4-8 Level 4
Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF 1006.16K hrs min. Telcordia SR-332 (Bellcore) ; 276.37Khrs min. MIL-HDBK-217F (25℃)
Packing 0.58Kg;24pcs /15Kg /0.85CUFT
Dimension 140*63*32mm (L*W*H)
P/No. Output Voltage Renge
RATED CURRENT Voltage Tol.
Effi.
XLG-100[]-12-[] 12V 8A ±3.0% 92%
XLG-100[]-24-[] 24V 4A ±2.0% 92%
  CONSTANT CURRENT REGION   CURRENT TOLERANCE  
XLG-100[]-L-[] 71 ~ 142V 700mA ±5% 92.5%
XLG-100[]-H-[] 27 ~ 56V 2100mA ±5% 91%
 
Download PDF Here
< back >
 
--- E-Star Power Development Co., Ltd.