DC input voltage
range |
A: 9 ~ 18VDC
B: 18 ~ 36VDC
C: 36 ~ 72VDC |
Over Load Protection |
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over Voltage Protection |
6 ~ 7.5V , 14 ~ 16.5V , 27 ~ 32.5V
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
SHORT CIRCUIT |
Recovers automatically after fault condition is
removed |
Isolation resistance |
I/P-O/P: 1.5KVAC
I/P-FG: 1.5KVAC
O/P-FG: 0.5KVAC |
Working temperature |
-20°C ~ +55°C (refer to output derating curve), 20~90%RH
non-condensing |
Safety standards |
EAC TP TC 004 approved, IEC 62368-1 CB approved by Dekra |
EMC CONDUCTION & RADIATION |
Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,6,8; ENV50204, EN 55024, light industry level, criteria A, EAC TP TC 020 |
Packing |
0.15kg;72pcs/10.8kg/0.82CUFT |