Line and load regulation |
±1.0% at 10% ~ 100% load, ±2.0% |
Over Load Protection |
Above 105% rated output power
Protection type : Over power limiting, recovers automatically after fault condition is removed |
Over Voltage Protection |
7.25 ~ 9V, -7.25 ~ -9V, 13.8 ~ 18V, -13.8 ~ -18V, 17.3 ~ 22.5V, -17.3 ~ -22.5V |
SHORT CIRCUIT |
Recovers automatically after fault condition is
removed |
Isolation resistance |
I/P-O/P: 100M Ohms/500VDC 25°C 70%RH |
Safety standards |
UL62368-1, EAC TP TC 004 approved, Design refer to TUV EN62368-1 |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,6,8; EN55024, light industry level, criteria A, EAC TP TC 020 |
Packing |
0.03Kg; 180pcs/6.4Kg/0.94CUFT |
Dimension |