DC Input Voltage
Range |
A: 9.2 ~18VDC
B: 19 ~ 36VDC
C: 36~72VDC |
DC Adjustment Range |
5V: 4.5~5.5V,
12V: 11~16V,
24V: 23~30V |
Over Load Protection |
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage Protection |
5.75 ~ 6.75V/10% load 16.8 ~ 20V/10% load 31.5 ~ 37.5V/10% load
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
Working Temperature |
-10°C to +60°C (refer to output derating curve) |
Safety Standards |
Design refer to LVD, EAC TP TC 004 approved |
EMC Standards |
Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020
Compliance to EN61000-4-2,3,4,6,8, EN55024,heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
374.3K hrs min.(SD-25A) 365.9K hrs min.(SD-25B) 377.5K Hrs min.(SD-25C) MIL-HDBK-217F (25?) |
Packing |
0.38Kg; 45pcs/17.8Kg/0.9CUFT |