DC Input Voltage
Range |
B: 19 ~ 36VDC
C: 36~72VDC
D: 72~144VDC or 85~132VAC |
Over Load Protection |
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage Protection |
16.8V ~ 20V/10% LOAD, 31.5 ~ 37.5V/10% LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25?/ 70% RH |
Working Temperature |
-10°C to +60°C (refer to output derating curve) |
Safety Standards |
TUV EN62368-1(for D type only), IEC 62368-1 CB approved by TUV (for D type only) EAC TP TC 004 approved |
EMC Standards |
Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020 |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,6,8; ENV50204, light industry level, criteria A, EAC TP TC 020 |
MTBF |
296.2K hrs min.(SD-150B) 289.9K hrs min.(SD-150C) 289K Hrs min.(SD-150D) MIL-HDBK-217F (25?) |
Packing |
0.86Kg; 16pcs/14.5Kg/0.95CUFT |