VOLTAGE RANGE CONTINUOUS |
B:16.8 ~ 33.6Vdc
C:33.6 ~ 67.2Vdc
D:67.2 ~ 154Vdc |
Over Load Protection |
Constant current limiting 105~135% rated output power with auto-recovery |
Over Voltage Protection |
14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V 14.4 ~ 17.5V 28.8 ~ 35V 57.6 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover |
Working Temperature |
-40 ~ +55°C(no derating) ; +70°C@ 60% load by free air convection ; +70?(no derating with external base plate) |
Safety Standards |
UL62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 3, 6KV contact; criteria A |
Radiated Field |
EN61000-4-3 |
Level 3, 10V/m ; criteria A |
EFT / Burst |
EN61000-4-4 |
Level 3, 2KV ; criteria A |
Surge |
EN61000-4-5 |
Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A |
Conducted |
EN61000-4-6 |
Level 3, 10V ; criteria A |
Magnetic Field |
EN61000-4-8 |
Level 4, 30A/m ; criteria A |
Packing |
1.45Kg;10pcs/15.5Kg/0.8CUFT |