DC Adjustment Range |
3.3V: +/-10% rated output voltage |
Overload protection
|
120%~160% hiccup mode, auto-recovery |
Over voltage protection |
5V: 115%~135% rated output voltage |
Leakage Current |
Less than 1.0mA at 240VAC |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 1.5KVAC,
O/P-FG: 0.5KVAC, 1 minute |
Working temperature |
-10°C ~ 60°C (refer to output derating curve) |
Safety standards |
UL60950-1, TUV EN60950-1 approved |
EMC Conduction & Radiation |
EN55022 (CISPR 22) class B, EN61000-3-2, 3, EN61000-4-2,
3, 4, 5, 6, 11 |
Packing |
0.28kg; 54pcs / 16.2kg / 1.35CUFT (PT-6503) |