AC input voltage
range |
88 ~ 132VAC / 176 ~ 264VAC auto switch 248 ~ 370VDC [DC input operation possible by connecting AC/N(-), AC/L(+)] |
AC INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
Overload protection |
105 ~ 140% (+24V: above 6.5A) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
3.8 ~ 4.45V 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Working temperature |
-10°C ~ +60°C (refer to output derating
curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A, EAC TP TC 020 |
MTBF |
203.6Khrs min. MIL-HDBK-217F (25℃) |
Packing |
0.45Kg; 24pcs/12.5Kg/1.63CUFT |