Inrush current (Typ.) |
COLD START 30A/115VAC 65A/230VAC |
Overload protection |
115%~160% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
12.6 ~ 16.2V, 15.8 ~ 20.3V,
25.2 ~ 32.4V, 50.4 ~ 64.8V
Protection type : Shut off o/p voltage, clamping
by zener diode |
Working temperature |
-30°C ~ +80°C (Refer to "Derating curve") |
Safety standards |
IEC62368-1, UL62368-1, TUV EN62368-1, EAC TP TC 004 approved; Design refer to EN60335-1(by request) |
Harmonic Current (Note 5) |
EN61000-3-2 |
Class A |
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
Surge |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
310Khrs min. MIL-HDBK-217F (25℃); 1694.28Khrs min. Telcordia TR/SR-332 (Bellcore) (25℃) |
Packing |
PCB mounting style : 0.197Kg;60pcs/11.8Kg/0.94CUFT
Screw terminal style :0.219Kg;50pcs/12Kg/0.56CUFT |
Dimension |
PCB mounting style : 87*52*29.5mm (L*W*H)
Screw terminal style : 109*52*33.5mm (L*W*H) |