AC Current (Typ.) |
0.75A/115VAC 0.5A/230VAC 0.375A/277VAC |
Inrush current (Typ.) |
COLD START 25A/115VAC 45A/230VAC |
Overload protection |
105% ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
5.25 ~ 6.75V 12.6 ~ 16.2V 15.75 ~ 20.25V 25.2 ~ 32.4V 50.4 ~ 64V
Protection type : Shut off o/p voltage, clamping
by zener diode |
Working temperature |
-30°C ~ +70°C (Refer to "Derating curve") |
Safety standards |
IEC62368-1, UL62368-1, TUV EN62368-1, EN60335-1, EAC TP TC 004, BSMI CNS14336-1 approved |
Conducted |
EN55032(CISPR32), CNS13438 |
Class B |
Radiated |
EN55032(CISPR32), CNS13438 |
Class B |
Harmonic Current (Note 5) |
EN61000-3-2 |
Class A |
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
Surge |
EN61000-4-5 |
Level 3,1KV/L-N, criteria A |
Voltage Dips and interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
593.3Khrs min. MIL-HDBK-217F (25℃) |
Packing |
PCB mounting style : 0.094Kg;144pcs/14.5Kg/0.94CUFT Screw terminal style :0.113Kg;120pcs/14.6Kg/0.83CUFT |
Dimension |
PCB mounting style : 69.5*39*24mm (L*W*H) Screw terminal style : 91*39.5*28.5mm (L*W*H) |