Over Load protection |
115 ~ 170% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
3.7~4.6V, 5.6~6.75V, 8.63~10.5V, 14~17V, 17.25~20.25V, 27.6~32.4V, 31.05~36.45V, 39.7~46.8V, 53.3~64.8V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-30°C ~ 70°C (refer to output derating curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 1.5KVAC,
O/P-FG: 0.5KVAC |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
649.1K hrs min. MIL-HDBK-217F (25℃ ) |
Packing |
0.085kg; 120pcs / 11.2kg / 0.97CUFT |