Switching Mode Power Supply |
|
|
|
|
|
|
|
|
|
AC DC Power Supply > Switching Mode Power
Supply > Open Frame Type > Single Output > 500W > EPP-500 |
|
Features
: |
* 5"x3" miniature size
* 320W convection, 500W force air
* 550W peak power (3sec.)
* Universal AC input / Full range
* EMI for both Class I and Class II configuration
* -30~ +70°C wide range operating temperature
* No load power consumption < 0.5W by PS_ON control
* High efficiency up to 94%
* Protections: Short circuit / Overload/ Over voltage / Over temperature
* 5Vdc standby output, 12Vdc fan supply, Power Good, Power Fail and remote sense
* Operating altitude up to 5000 meters (Note.5)
* LED indicator for power on
* 3 years warranty
|
Model No. : |
EPP-500 |
|
AC input voltage
range |
80 ~ 264VAC 113 ~ 370VDC |
AC INRUSH CURRENT (Typ.) |
COLD START 40A/115VAC 80A/230VAC |
Leakage Current |
<0.75mA / 240VAC |
Over Load protection |
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
13.2 ~ 15.6V, 16.5~19.5V, 19.8~23.4V, 26.4~31.2V, 29.7~35.1V, 39.6~46.8V, 52.8~62.4V, 59.4~70.2V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature protection |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
Working temperature |
-30°C ~ 70°C (refer to output load derating curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EN60335-1, IEC62368-1, EAC TP TC 004 approved |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
EMC Emission |
Parameter |
Standard |
Test Level / Note |
Conducted |
EN55032(CISPR32),CNS13438 |
Class I:ClassB, ClassII:ClassA |
Radiated |
EN55032(CISPR32),CNS13438 |
Class A |
Harmonic Current |
EN61000-3-2 |
Class A |
Voltage Flicker |
EN61000-3-3 |
----- |
EMC Immunity |
EN55024, EN61000-6-2 |
Parameter |
Standard |
Test Level / Note |
ESD |
EN61000-4-2 |
Level 3, 8KV air; Level 2, 4KV contact, criteria A |
RF field susceptibility |
EN61000-4-3 |
Level 3, criteria A |
EFT bursts |
EN61000-4-4 |
Level 3, criteria A |
Surge susceptibility |
EN61000-4-5 |
Level 4,2KV/L-N, criteria A |
Conducted susceptibility |
EN61000-4-6 |
Level 3, criteria A |
Magnetic field immunity |
EN61000-4-8 |
Level 4, criteria A |
Voltage dip, interruption |
EN61000-4-11 |
>98% dip 0.5 periods, 30% dip 25 periods,
>98% interruptions 250 periods |
MTBF |
194.1Khrs min. MIL-HDBK-217F (25℃) |
Packing |
0.46Kg; 30pcs/14.8Kg/1.03CUFT |
Dimension |
127*76.2*40mm (L*W*H) |
|
EPP-500:
5"x3" Green Open Frame Power Supply |
P/No. |
DC VOLTAGE
|
CURRENT RANGE
|
RATED POWER |
Tol.
|
R &
N
|
Effi. |
(convection) |
(25CFM) |
(convection) |
(25CFM) |
EPP-500-12 |
12V |
26.7A |
41.6A |
320.4W |
499.2W |
±3% |
200mV |
91% |
EPP-500-15 |
15V |
21.3A |
33.3A |
319.5W |
499.5W |
±3% |
200mV |
92% |
EPP-500-18 |
18V |
17.8A |
27.8A |
320.4W |
500.4W |
±3% |
200mV |
92.5% |
EPP-500-24 |
24V |
13.4A |
20.8A |
321W |
499.2W |
±2% |
200mV |
93% |
EPP-500-27 |
27V |
11.9A |
18.5A |
321.3W |
499.5W |
±2% |
200mV |
93.5% |
EPP-500-36 |
36V |
8.9A |
13.9A |
320.4W |
500.4W |
±1% |
200mV |
94% |
EPP-500-48 |
48V |
6.7A |
10.4A |
321.6W |
499.2W |
±1% |
200mV |
94% |
EPP-500-54 |
54V |
5.93A |
9.26A |
320.2W |
500W |
±1% |
200mV |
94% |
|
|