Over Load protection |
105 ~ 145% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
13.2~15.6V, 16.83~19.5V, 27.7~31.5V, 30.2~34.05V, 51.3~62.7V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature protection |
Protection type : Shut down o/p voltage, re-power on to recover |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 2KVAC,
O/P-FG: 0.5KVAC |
Working temperature |
-30°C ~ 70°C (refer to output load derating curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
207.1Khrs min. MIL-HDBK-217F (25℃) |
Packing |