AC INRUSH CURRENT |
Vin=240Vac, Cold start at 25℃...8.5A |
Leakage Current |
(Earth)..250uA, (Touch)...100uA |
MTBF |
Io=100%; Ta=25℃ per MIL-HDBK-217F...600k hours |
Emission and Immunity |
EN 55032: 2015+A11: 2020, EN 61000-6-3 2007+A1: 2011+AC: 2012, Class B
EN 61000-6-4:2019, 47 CFR FCC Part 15 Subpart B, EN 61204-3:2018,
EN 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019
EN 55035: 2017+A11: 2020, EN 61204-3: 2018, EN 61000-6-1: 2019, EN 61000-6-2: 2019
EN 61000-6-4-2, 3, 4, 5, 6, 8, 11 |
Safety |
Class I, IEC/EN/UL 62368-1 |
Dimension |
4.60x2.40x0.67 Inches
(116.8x61.0x17.0 mm) |