Over Load protection |
Normally works within 105~130% rated output power
for 3 sec. and then shut down o/p voltage with auto-recovery
130~150% rated power or short circuit, constant
current limiting within 3 sec. and shut down o/p
voltage with auto-recovery |
Over Voltage protection |
115%~135% rated output voltage |
Over Temperature protection |
95°C +/-5°C (TSW1)
Shut down o/p voltage, recovers automatically after
fault condition is removed |
Withstand voltage |
I/P-O/P: 4KVAC,
I/P-FG: 1.5KVAC,
O/P-FG: 0.5KVAC |
Working temperature |
-30°C ~ 70°C (refer to output derating curve) |
Safety standards |
EN61347-2-13, Ul1012, UL60950-1, EN60950-1 approved |
EMC Conduction & Radiation |
EN55015,EN55022 (CISPR22) Class B,
EN61000-3-2, CLASS C ( =60% load), EN61000-3-3;
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024,
heavy industry level (surge 4KV), criteria A |