E-Star Power Supply Mail to Us power supply products
| AC DC Power Supply | | Medical Power Supply | | DC DC Power Supply | | AC POWER CORD | - | Contact Us | - | Home |
 
AC DC Power Supply
> Switching Mode Power Supply
> Open Frame Type / Single
> LPS-100
 
 
 
 
 
Switching Mode Power Supply> Open Frame Type > Single Output > 100W
Power Supply LPS-100
Features : Universal AC input / Full range
PF> 0.98@115VAC; >0.95@230VAC
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Approvals: UL / CUL / TUV / CB / CE
Fixed switching frequency at 134KHz
100% full load burn-in test
Leakage current <2mA @ 240VAC
3 years warranty (2 years for LPS-100)
Model No. LPS-100
AC input voltage range 88~264VAC or 120~370VDC (188~132 / 176~264VAC auto switch for LPS-100)
AC INRUSH CURRENT (Typ.) COLD START 60A/230VAC (30A for LPP-100)
LEAKAGE CURRENT <2.0mA / 240VAC
Overload protection 105%~140% hiccup mode, auto-recovery (LPS)
105%~150% constant current, auto-recovery (LPP)
Over voltage protection 115%~135% rated output voltage
Withstand voltage I/P-O/P: 3KVAC,
I/P-FG: 1.5KVAC, 1 minute
Working temperature -10°C ~ +60°C (refer to output derating curve)
Safety standards UL60950-1, TUV EN60950-1 approved
EMC Conduction & Radiation EN55022 class B, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 11, ENV50204
Connection 5+8P/ 3.96 mm pitch, JST P/N: B5P / B8P-VH
Packing 0.45kg; 24pcs / 12.5kg / 1.76CUFT (LPS-100),
0.51kg; 24pcs / 13.9kg / 1.76CUFT (LPP-100)
Dimension 222x62x32 mm (L*W*H)
LPS-100: AC DC Single output open frame power supply without PFC
P/No. Output
Tol.
R & N
Effi.
LPS-100-3.3 3.3V, 0~20A +/-3% 150mV 69%
LPS-100-5 5V, 0~20A +/-3% 100mV 77%
LPS-100-7.5 7.5V, 0~13.3A +/-2% 100mV 77%
LPS-100-12 12V, 0~8.4A +/-2% 100mV 79%
LPS-100-13.5 13.5V, 0~7.5A +/-2% 100mV 79%
LPS-100-15 15V, 0~6.7A +/-2% 100mV 80%
LPS-100-24 24V, 0~4.2A +/-1% 150mV 80%
LPS-100-27 27V, 0~3.8A +/-1% 150mV 81%
LPS-100-48 48V, 0~2.1A +/-1% 200mV 81%
 
Download PDF Here
< back >
 
--- E-Star Power Development Co., Ltd.