AC INRUSH CURRENT (Typ.) |
COLD START 18A/115VAC 35A/230VAC |
Overload protection |
122% ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Withstand voltage |
I/P-O/P: 3KVAC
I/P-FG: 1.5KVAC
O/P-FG: 0.5KVAC |
Working temperature |
-20°C ~ +70°C (refer to output derating
curve) |
Safety standards |
UL60950-1, TUV EN60950-1 approved |
EMC Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2, -3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,
EN55024, EN61000-6-2 (EN50082-2), heavy industry
level, criteria A |
Packing |
0.24kg; 48pcs/ 12.5Kg/ 0.84CUFT |