AC Inrush Current (Typ.) |
COLD START 25A/115VAC 50A/230VAC |
Overload protection |
90 ~ 125W output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
Over voltage protection |
CH1:13.8 ~ 16.2V CH1:27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Working temperature |
10°C ~ +60°C (Refer to output load derating curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
MTBF |
288.1K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.24Kg; 63pcs/16Kg/1.28CUFT |