AC input voltage
range |
100 ~ 264VAC, 141 ~370VDC (90 ~ 100VAC 90% load max.) |
Overload protection |
105% ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
CH1: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
Working temperature |
-10°C ~ +50°C, 60°C with cooling fan (Refer
to output load derating curve) |
Safety standards |
UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A, EAC TP TC 020 |
MTBF |
323K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.51Kg; 24pcs/13.1Kg/1.19CUFT |
Dimension |
177.8*107.95*46.5mm (L*W*H) |