AC input voltage
range |
100~264VAC; 141~370VDC (90 ~ 100VAC
90% load max.) |
Overload protection |
105% ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
CH1: 5.75 ~ 6.75VDC
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Withstand voltage |
I/P-O/P: 3KVAC
I/P-FG: 1.5KVAC
O/P-FG: 0.5KVAC |
Working temperature |
-10°C ~ +50°C, 60°C with cooling fan (Refer
to output load derating curve) |
Safety standards |
UL60950-1, TUV EN60950-1 approved |
EMC Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2, -3
Compliance to EN61000-4-2, 3, 4, 5, 6, 11; ENV50204,
light industry level, criteria A |
Packing |
0.51kg; 24pcs/ 13.1Kg/ 1.19CUFT |
Dimension |
177.8*107.95*46 mm (L*W*H) |