AC Inrush Current (Typ.) |
Cold start 30A/115VAC 60A/230VAC |
Overload protection |
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
4.62 ~ 5.46V, 5.75 ~ 6.75V, 13.2 ~ 15.6V, 16.5 ~ 19.5V, 26.4 ~ 31.2V, 39.6 ~46.8V, 52.8 ~ 62.4V
Protection type :Shut down O/P voltage,re-power on to recover |
Working temperature |
-20 ~ +70℃(Refer to “Derating Curve") |
Safety standards |
UL 62368-1,TUV EN62368-1,EN60335-1, CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16 |
Withstand voltage |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC |
EMC EMISSION |
Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 |
MTBF |
168K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.905kg; 16pcs/15.48kg/0.82CUFT |