Overload protection |
105 ~ 130% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
3.8~4.5V, 4.5~5.3V, 5.75~6.75V, 13.8~16.2V, 18.8~21.8V, 27.6~32.4V, 32.9~38.3V, 58.4~68V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, recovers automatically after temperature goes down |
Working temperature |
-30°C ~ 70°C (refer to "Derating Curve") |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 , CCC GB4943.1 BSMI CNS14336-1approved , |
Withstand voltage |
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020,GB/T 9254, CNS13438 Class B |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
187.7K hrs min. MIL-HDBK-217F (25℃ ) |
Packing |
1.3Kg; 9pcs/12.7Kg/0.7CUFT |