Overload protection |
105%~135%
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
2.88~3.38V, 3.8~4.5V, 4.5~5.3V, 5.75~6.75V, 9.4~10.9V, 13.8~16.2V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, recovers automatically after temperature goes down |
Withstand voltage |
I/P-O/P: 3.0KVAC
I/P-FG: 2KVAC
O/P-FG:0.5KVAC |
Working temperature |
-30 ~ +70℃ (Refer to "Derating Curve") |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1, AS/NZS 60950.1 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
MTBF |
206.5K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.9kg; 15pcs / 14.5Kg / 0.78CUFT |