Overload protection |
105 ~135% rated output power
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover |
Over voltage protection |
5.75~6.75V, 13.8~16.8V, 17~20.5V, 27.6~32.4V, 31~36.5V, 57.6~67.2V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-20 ~ +70℃(Refer to "Derating Curve") |
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety standards |
UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved |
Withstand voltage |
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC |
EMC IMMUNITY |
EN55024, EN61000-6-2, BSMI CNS13438 |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
Surge |
EN61000-4-5 |
Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line |
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
265.3K hrs min. Telcordia SR-332 (Bellcore) ; 90.3K hrs min. MIL-HDBK-217F (25℃) |
Packing |
3.0Kg; 4pcs/13Kg/1.19CUFT |