OVERLOAD |
105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage protection |
13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 56.6 ~ 66.2V
Protection type : Shut down o/p voltage, re-power on to recover |
Withstand voltage |
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC |
Working temperature |
-20 ~ +60℃(Refer to "Derating Curve") |
Safety standards |
UL62368-1, CSA C22.2 No. 62368-1, TUV EN62368-1, CCC GB4943.1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved |
EMC IMMUNITY |
EN55024, EN61000-6-2, CCC GB17625.1, GB/T9254, BSMI CNS13438 |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
Surge |
EN61000-4-5 |
Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line |
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 peniods,
>95% interruptions 250 periods |
MTBF |
313.1K hrs min. Telcordia SR-332 (Bellcore) ; 116.75K hrs min. MIL-HDBK-217F (25℃) |
Packing |
1.95Kg; 6pcs/12.7Kg/1.15CUFT |