Input Voltage
Range
|
90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC |
Overload protection |
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage protection |
14.5 ~ 16.5V, 18.2 ~ 20.6V, 29 ~ 33V, 58 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-20 ~ +70℃(Refer to "Derating Curve") |
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 2KVAC,
O/P-FG: 0.5KVAC |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved |
EMC IMMUNITY |
EN55024, EN61000-6-2, BSMI CNS13438 |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
Surge |
EN61000-4-5 |
Level 4, 2KV/Line-Line 4KV/Line-Earth |
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
274.3K hrs min. Telcordia SR-332 (Bellcore) ; 94.4K hrs min. MIL-HDBK-217F (25℃) |
Packing |
1.93Kg ; 8pcs/16.4Kg/1.53CUFT |