Switching Mode Power Supply |
|
|
|
|
|
|
|
|
|
AC DC Power Supply >
Switching Mode Power Supply > Enclosed Type > Single Output
> 150W > LRS-150 |
|
Features |
* AC input range selectable by switch
* Withstand 300VAC surge input for 5 second
* No load power consumption < 0.5W
* Miniature size and 1U low profile
* Protections: Short circuit / Overload / Over voltage/
Over temperature
* Cooling by free air convection
* Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, 2-16 for household appliances
* Operationg altitude up to 5000 meters
* Withstand 5G vibration test
* High efficiency, long life and high reliability
* LED indicator for power on
* Over voltage category III
* 100% full load burn-in test
* 3 years warranty |
Model No. |
LRS-150
|
|
Input Voltage
Range
|
85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC) |
AC Inrush Current (Typ.) |
COLD STAR 60A/230VAC |
Leakage Current |
<0.75mA / 240VAC |
Overload protection |
110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over voltage protection |
13.8 ~ 16.2V, 18.75 ~ 21.75V, 28.8 ~ 33.6V, 41.4 ~ 48.6V, 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-30 ~ +70℃(Refer to "Derating Curve") |
Vibration |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety standards |
UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI
CNS14336-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005,
AS/NZS 62368.1(by CB) approved |
Withstand voltage |
I/P-O/P:4KVAC
I/P-FG:2KVAC
O/P-FG:1.25KVAC |
EMC EMISSION |
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load),
BS EN/EN61000-3-3,GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) |
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,
heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) |
MTBF |
2707.7K hrs min. Telcordia SR-332 (Bellcore) ; 558.2Khrs min. MIL-HDBK-217F (25℃) |
Dimension |
159*97*30mm (L*W*H) |
Packing |
0.48Kg ; 30pcs/15.4Kg/0.75CUFT |
|
P/No. |
Output
Voltage
|
RATED POWER
|
Output
Rated Current |
Tol.
|
R &
N
|
Effi. |
LRS-150-12 |
12V |
150W |
12.5A |
±1% |
150mV |
87.5% |
LRS-150-15 |
15V |
150W |
10A |
±1% |
150mV |
88.5% |
LRS-150-24 |
24V |
156W |
6.5A |
±1% |
200mV |
89% |
LRS-150-36 |
36V |
154.8W |
4.3A |
±1% |
200mV |
89% |
LRS-150-48 |
48V |
158.4W |
3.3A |
±1% |
200mV |
90% |
|
|
Download
PDF Here |
|
< back > |
|
|