Overload protection |
105%~135% rated output power
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed |
Over voltage protection |
3.96~4.62V, 6~7V, 9.4~10.9V, 14.4~16.8V, 18.8~21.8V, 30~34.8V, 41.4~48.6V, 57.6~67.2V
Protection type : Shut down o/p voltage, re-power on to recover |
Withstand voltage |
I/P-O/P: 3KVAC
I/P-FG: 2KVAC
O/P-FG: 0.5KVAC |
Working temperature |
-40 ~ +70℃(Refer to "Derating Curve") |
Safety standards |
UL62368-1,TUV EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
394.8K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.47kg; 30pcs / 15.0kg / 0.97CUFT |