E-Star Power Supply Mail to Us power supply products
| AC DC Power Supply | | Medical Power Supply | | DC DC Power Supply | | AC POWER CORD | - | Contact Us | - | Home |
 
AC DC Power Supply
> Switching Mode Power Supply
> Enclosed Type

> Single Output

> 150W

> HRP-150N

 
 
 
AC DC Power Supply > Switching Mode Power Supply > Enclosed Type > Single Output > 150W > HRP-150N
Power Supply HRP-300N
Features : * Universal AC input / Full range
* Built-in active PFC function, PF>0.95
* 200% peak power capability
* High efficiency up to 89%
* Withstand 300VAC surge input for 5 seconds
* Protections: Short circuit / Overload/ Over voltage/ Over temperature
* Cooling by free air convection
* 1U low profile 38mm
* Built-in remote sense function
* 5 years warranty
Model No. : HRP-150N
AC input voltage range 85~264VAC; 120~370VDC
AC Inrush Current (Typ.) 35A/115VAC 70A/230VAC
Overload protection Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >220% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
Over voltage protection 14.4 ~ 16.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
Leakage Current <1.0mA / 240VAC
Withstand voltage I/P-O/P: 3KVAC
I/P-FG: 2KVAC
O/P-FG: 0.5KVAC
Working temperature -40 ~ +70℃(Refer to "Derating Curve")
Safety standards UL62368-1, TUV EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
EMC EMISSION Parameter Standard Test Level / Note
Conducted EN55032 Class B
Radiated EN55032 Class B
Harmonic current EN61000-3-2 Class A
Voltage Flicker EN61000-3-3 ---
EMC IMMUNITY EN55035 , EN61000-6-2(EN50082-2)
Parameter Standard Test Level / Note
ESD EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact
RF field EN61000-4-3 Level 3, 10V/m
EFT/ Burst EN61000-4-4 Level 3, 2KV
Surge EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted EN61000-4-6 Level 3, 10V
Magnetic Field EN61000-4-8 Level 4, 30A/m
Voltage Dips and Interruptions EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
MTBF

578.15K hrs min. Telcordia TR/SR-332 (Bellcore) ; 221.71K hrs min. MIL-HDBK-217F (25℃)

Packing 0.54Kg; 24pcs/12.96Kg/0.9CUFT
Dimension 159*97*38mm (L*W*H)
Model No. DC VOLTAGE
CURRENT RANGE
RATED POWER
Tol.
R & N
Effi.
HRP-150N-12 12V 0~13A 156W ±1.5% 120mV 88%
HRP-150N-24 24V 0~6.5A 156W ±1.5% 150mV 88%
HRP-150N-36

36V

0~4.3A

154.8W ±1.5% 200mV 89%
HRP-150N-48

48V

0~3.3A

158.4W ±1.5% 240mV 89%
 
Download PDF Here
< back >
 
--- E-Star Power Development Co., Ltd.