Input Voltage
Range
|
85~264VAC (277VAC operational)
120~370VDC(390VDC operational) |
AC Inrush Current (Typ.) |
COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC |
Overload protection |
105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage protection |
13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V 26 ~ 30V 32.5 ~ 36.5V 39.5 ~ 43.5V 46 ~ 50V 52.5 ~ 56.5V 59 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-40 ~ +70℃(Refer to "Derating Curve") |
Vibration |
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC |
Safety standards |
UL62368-1,TUV EN62368-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, EAC TP TC 020 |
MTBF |
76.9K hrs min. MIL-HDBK-217F (25℃) |
Packing |