Input Voltage
Range
|
85~264VAC (277VAC operational) 120~370VDC(390VDC operational) |
Overload protection |
105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage protection |
13.5 ~ 18V 17.5 ~ 21.5V 27 ~ 34V 43 ~ 49V 55 ~ 63V 60 ~ 67V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-55 ~ +70℃ (Refer to "Derating Curve") |
Vibration |
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC |
Safety standards |
UL62368-1, IEC/EN62368-1, IP65 (or IP68 for HEP-240 Blank-Type), EAC TP TC 004 approved; |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020 |
MTBF |
171.3K hrs min. MIL-HDBK-217F (25℃) |
Packing |
1.3Kg; 12pcs/16.6Kg/0.84CUFT |