Overload protection |
105 ~ 115% rated output power
Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover |
Over voltage protection |
31.5 ~ 37.5V, 63 ~ 75V
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-30 ~ +70℃(Refer to "Derating Curve") |
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety standards |
UL62368-1, CSA C22.2 No. 62368-1, TUV EN62368-1, EAC TP TC 004 approved |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
EMC IMMUNITY |
EN55024 , EN61204-3, EN61000-6-2 |
ESD |
EN61000-4-2 |
Level 3, 8KV air ; Level 2, 4KV contact |
Surge |
EN61000-4-2 |
2KV/Line-Line 4KV/Line-Earth |
Voltage Dips and Interruptions |
EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
MTBF |
176.1K hrs min. Telcordia SR-332 (Bellcore) ; 44.5K hrs min. MIL-HDBK-217F (25℃) |
Packing |
2.65Kg;4pcs/11.6Kg/0.87CUFT |