Power Factor (Typ.)
|
PF≡0.9 at 75~100% load, 115VAC/230VAC; PF≡0.9
at 85~100% load 277VAC (Please refer to "Power
Factor Characteristic" curve) |
Over Current protection |
95 ~ 110%
Protection type : Constant current limiting, recovers
automatically after fault condition is removed |
SHORT CIRCUIT protection |
Hiccup mode, recovers automatically after fault
condition is removed. |
Over Voltage protection |
14V ~ 60V
Protection type : Shut off o/p voltage, clamping
by zener diode |
Working temperature |
-30 ~ +60°C (Refer to "Derating Curve") |
Safety standards |
IEC61347-1, IEC61347-2-13, TUV EN61347-1, EN61347-2-13,
UL8750, CSA C22.2 No. 250.0-08, J61347-1, J61347-2-13,
IP64 approved |
EMC EMISSION |
Compliance to EN55015, EN61000-3-2 Class C
(≡75% load); EN61000-3-3 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61547,
light industry level, criteria A |
Packing |
0.18Kg; 60pcs/ 12.8Kg/ 0.9CUFT |