AC input voltage
range |
A : With AC input 90~ 135VAC.
B : With AC input 180~ 295VAC. |
Power Factor (Typ.)
|
PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC
at full load (Please refer to "Power Factor
Characteristic" curve) |
AC Inrush Current (Typ.) |
COLD START 20A (twidth=25µs measured
at 50% Ipeak) at 230VAC |
SHORT CIRCUIT protection |
Hiccup mode, recovers automatically after fault
condition is removed. |
Working temperature |
-30°C ~ +50°C (Refer to "Derating Curve") |
Safety standards |
UL 8750,CSA C22.2 No.250.0-08(except for PLD-16-350);ENEC
EN 613471-1,EN 61347-2-13 independent,EN62384(for
B type only)approved |
EMC EMISSION |
Compliance to EN55015 (B type only), EN61000-3-2
Class C ; EN61000-3-3, FCC part 18 non-consumer
equipment (A type only) |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,
light industry level, criteria A |
Packing |
0.19Kg; 72pcs/ 14.7Kg/ 0.92CUFT |