AC Inrush Current (Typ.) |
COLD START 60A(twidth=550μs measured at 50% Ipeak) at 230VAC |
Over Current protection |
105 ~ 115%
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V
Protection type : Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, re-power on to recover |
Working temperature |
-40 ~ +70℃(Refer to "Derating Curve") |
Safety standards |
EN61558-1,-2-16 listed; EN60335-1 listed(except for OWA-90E-42,48,54); IP67 approved |
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN55014-1, EN61000-3-2,-3 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A |
Packing |
0.92Kg; 16pcs/15.7Kg/1.01CUFT |