Over current protection |
Above 105% rated output power
Hiccup mode, recovers automatically after fault
condition is removed |
Working temperature |
-25°C ~ 70°C (Refer to output load derating
curve) |
Safety standards |
Design refer to UL1310 Class 2, TUV EN60950-1,
EN61347-2-13, CAN/CSA C22.2 No. 223-M91, IP67 approved |
EMC Conduction & Radiation |
Compliance to EN55022 (CISpr22) ClassB, FCC Part
15
Compliance to EN61000-3-2, -3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204,
EN55024, light industry level, criteria A |
Packing |
0.175Kg; 70 pcs/ 13.3Kgs/ 0.66CUFT |