Power Factor (Typ.)
|
PF>0.95/230VAC,
PF>0.92/ 277VAC at full load (please refer
to "Power Factor Characterstic" Curve)
|
SHORT CIRCUIT protection |
Channel shut down when eachchannel fault, re-power on to recovery |
Over Voltage protection |
130%~145%
Protection type : Shut down o/p voltage with auto-recovery
or re-power on to recovery |
OVER TEMPERATURE |
100°C +/-10°C (RTH2)
Protection type : Shut down o/p voltage, recovers
automatically after temperature goes down |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC |
Working temperature |
-30 ~ +70°C
(Refer to "derating curve") ; -40°C can power on |
Safety standards |
IP67 approved;
Design refer to EN61347-1, EN61347-2-13, UL8750 |
EMC Conduction & Radiation |
Compliance to EN55015, EN61000-3-2 Class C (>=75% load); EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge
4KV), criteria A |
Packing |
1.27Kg; 12pcs/16.2Kg/1.02CUFT |