PWM
DIMMING
&
ON/OFF
CONTROL
|
REMOTE ON/OFF |
Leave open if not used |
Power ON with dimming: PWM signal >2~8VDC or open circuit, between PWM DIM and DIM |
Power OFF : PWM signal <0.5VDC or short or PWM duty is equal to 0%, between PWM DIM and DIM |
QUIESCENT INPUT CURRENT
IN SHUTDOWN MODE(Typ.) |
7mA when PWM dimming OFF |
ANALOG
DIMMING
&
ON/OFF
CONTROL |
REMOTE ON/OFF |
DIMLeave
open if not used |
Power on with dimming: DC input >0.25~8VDC or open circuit, between Analog DIM and DIM |
Power off : DC input <0.2VDC or short, between Analog DIM and DIM |
MAX OPERATION VOLTAGE |
8V; The output current remains constant when voltage changes from 1.3V to 8V |
QUIESCENT INPUT CURRENT
IN SHUTDOWN MODE(Typ.) |
7mA when Analog dimming OFF |
SHORT CIRCUIT protection |
Protection type : Power OFF and fuse open |
Over Voltage protection |
100V, 100V, 75V, 50V, 146V, 100V, 75V, 50V
Protection type : Constant output voltage and shut off o/p current, recovers automatically after fault condition is removed |
Working TEMPERATURE |
-40 ~ +70℃(Refer to "Derating Curve") |
Safety standards |
IP67 approved;
Design refer to EN61347-1, EN61347-2-13, UL8750 |
EMC IMMUNITY |
Compliance to EN61547,EN61000-4-2,3,4,6,8; light industry level, criteria A |
Packing |
138g;100pcs/14.8Kg/0.83CUFT[(Blank) type or (Blank) DA type],1.04CUFT(W type or WDA type) |