AC input voltage
range |
180 ~ 528VAC 254VDC ~ 747VDC |
Power Factor (Typ.)
|
PF¡Ù0.98/230VAC
PF¡Ù0.97/277VAC
PF¡Ù0.95/347VAC
PF¡Ù0.93/480VAC at full load (Please
refer to "Power Factor Characteristic"
curve) |
AC Inrush Current (Typ.) |
COLD START 35A(twidth=790£g s measured at 50% Ipeak) at 480VAC |
Over Current protection |
95 ~ 108% Protection type : Constant current
limiting, recovers automatically after fault condition
is removed |
SHORT CIRCUIT protection |
Constant current limiting, recovers automatically
after fault condition is removed |
Over Voltage protection |
110%~140%
Protection type : Shut down o/p voltage with auto-recovery
or re-power on to recovery |
OVER TEMPERATURE |
100°C +/-10°C (RTH2)
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC |
Working temperature |
-40 ~ +70°C (Refer to "Derating Curve") |
Safety standards |
UL8750, CSA C22.2 No. 250.0-08, IP65 or IP67 approved |
EMC Conduction & Radiation |
Compliance to EN55015, EN61000-3-2 Class C (¡Ù55% load,¡Ù60% load only for 12V model ) ; EN61000-3-3, FCC part 15 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge 4KV), criteria A |
Packing |
1.24Kg; 12pcs/15.9Kg/0.78CUFT |