AC input voltage
range |
180 ~ 480VAC 254VDC ~ 679VDC |
Power Factor (Typ.)
|
PF>=0.98/230VAC
PF>=0.98/277VAC
PF>=0.97/347VAC
PF>=0.94/440VAC
PF>=0.93/440VAC only for 15V model
at full load (Please refer to "Power Factor
Characteristic" curve) |
Over Current protection |
95 ~ 108% Protection type : Constant current
limiting, recovers automatically after fault condition
is removed |
SHORT CIRCUIT protection |
Constant current limiting, recovers automatically
after fault condition is removed |
Over Voltage protection |
110%~140%
Protection type : Shut down o/p voltage with auto-recovery
or re-power on to recovery |
OVER TEMPERATURE |
100°C +/-10°C (RTH2)
Protection type : Shut down o/p voltage, recovers
automatically after temperature goes down |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC |
Working temperature |
-40 ~ +70°C (Refer to "Derating Curve") |
Safety standards |
UL8750, CSA C22.2 No. 250.0-08(except for 42V,48V, 54V), IP65 or IP67 approved |
EMC Conduction & Radiation |
Compliance to EN55015, EN61000-3-2 Class C (>=50% load,>=60% load only for 15V model ) ; EN61000-3-3, FCC part 15 class B
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge 4KV), criteria A |
Packing |
1.18Kg; 12pcs/15.2Kg/0.74CUFT |