AC input voltage
range |
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
Power Factor (Typ.)
|
PF≧0.98/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC @full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
SHORT CIRCUIT protection |
Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
300 ~ 340V, 150 ~ 170V
Shut down o/p voltage with auto-recovery or re-power on to recovery |
INRUSH CURRENT(Typ.) |
COLD START 60A(twidth=410 s measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
OVER TEMPERATURE |
Shut down o/p voltage, re-power on to recover |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC |
Working temperature |
Tcase=-40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved |
EMC EMISSION |
Compliance to EN55015, EN61000-3-2 Class C (@ load≧50%) ; EN61000-3-3 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) |
MTBF |
861.8K hrs min. Telcordia SR-332 (Bellcore) ; 309.7K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.84Kg; 16pcs/14.4Kg/0.54CUFT |
Dimension |
195.6*61.5*38.8 mm (L*W*H) |