AC input voltage
range |
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
Power Factor (Typ.)
|
PF≧0.98/115VAC, PF≧0.97/230VAC, PF≧0.95/277VAC @full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
SHORT CIRCUIT protection |
Constant current, recovers automatically after fault condition is removed |
Over Voltage protection |
432 ~ 473V, 345 ~ 382V, 289 ~ 322V, 215 ~ 246V, 173 ~ 197V
Shut down output voltage, re-power on to recovery |
OVER TEMPERATURE |
Shut down output voltage, re-power on to recovery |
INRUSH CURRENT(Typ.) |
COLD START 35A(twidth=1800 s measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC |
Working temperature |
Tcase=-40 ~ +90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.14,GB19510.1; IP65 or IP67 approved |
EMC EMISSION |
Compliance to EN55015,EN61000-3-2 Class C (@load≧50%); EN61000-3-3; GB17743, GB17625.1 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) |
MTBF |
421.1K hrs min. Telcordia SR-332(Bellcore) ; 110.5K hrs min. MIL-HDBK-217F (25℃) |
Packing |
2.8Kg;4pcs/12.2Kg/0.58CUFT |