Features : * Constant Voltage + Constant Current mode output
* Metal housing with class I design
* Built-in active PFC function
* Class 2 power unit
* IP67 / IP65 design for indoor or outdoor installations
* Function outions: output adjustable via potentiometer; 3 in 1 dimming, Timer dimming
* Typical lifetime > 62000 hours
* 7 years warranty
Model No. : HLG-40H
AC input voltage range

90 ~ 305VAC, 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)

Power Factor (Typ.)
PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC @ full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
FREQUENCY RANGE 47 ~ 63Hz
INRUSH CURRENT(Typ.)

COLD START 50A(twidth=210 s measured at 50% Ipeak) at 230VAC; Per NEMA 410

Over Current protection

95%~108%
Constant current limiting, recovers automatically after fault condition is removed

Over Voltage protection 15 ~ 21V, 18 ~ 24V, 23 ~ 30V, 28 ~ 35V, 35 ~ 43V, 41 ~ 49V 48 ~ 58V, 54 ~ 65V, 59 ~ 68V
Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
Leakage Current <0.75mA / 277VAC
Withstand voltage

I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC

Working temperature Tcase= -40 ~ +80℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
Safety standards UL8750(type"HL"), CSA C22.2 No. 250.0-08 (except for 48V, 54V), TUV EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved ;optional models for J61347-1, J61347-2-13 ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C (@ load≧60%) ; EN61000-3-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV)
MTBF 1131.9K hrs min. Telcordia SR-332 (Bellcore) ; 336.5K hrs min. MIL-HDBK-217F (25℃)
Packing 0.73Kg; 20pcs/15.6Kg/0.9CUFT
Dimension 171*61.5*36.8mm (L*W*H)
P/No. DC VOLTAGE CONSTANT CURRENT REGION RATED POWER RATED CURRENT Tol. R & N
Effi.
HLG-40H-12 12V 7.2~12V 39.96W 3.33A ±2.5% 150mVp-p 86.5%
HLG-40H-15 15V 9~15V 40.05W 2.67A ±2% 150mVp-p 86.5%
HLG-40H-20 20V 12~20V 40W 2A ±1% 150mVp-p 88%
HLG-40H-24 24V 14.4~24V 40.08W 1.67A ±1% 200mVp-p 88%
HLG-40H-30 30V 18~30V 40.2W 1.34A ±1% 200mVp-p 88.5%
HLG-40H-36 36V 21.6~36V 40.32W 1.12A ±1% 200mVp-p 88.5%
HLG-40H-42 42V 25.2~42V 40.32W 0.96A ±1% 200mVp-p 88.5%
HLG-40H-48 48V 28.8~48V 40.32W 0.84A ±1% 300mVp-p 89.5%
HLG-40H-54 54V 32.4~54V 40.5W 0.75A ±1% 300mVp-p 89.5%
 