AC
input voltage range |
90 ~ 305VAC, 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
Power Factor (Typ.)
|
PF≧0.98/115VAC, PF≧0.94/230VAC, PF≧0.9/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
AC Inrush Current (Typ.) |
COLD START 75A(twidth=680μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
Over Current protection |
95 ~ 108%
Protection type : Constant current limiting, recovers
automatically after fault condition is removed |
Over Voltage protection |
43 ~ 52V, 52 ~ 63V, 62 ~ 85V
Shut down and latch off o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, recovers automatically after temperature goes down |
Working temperature |
Ta=-40 ~ +45℃(Please refer to " OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750,CSA C22.2 No.250.13-12; ENEC EN61347-1,EN61347-2-13,EN62384, GB19510.1,GB19510.14 approved |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2.0KVAC
O/P-FG:0.5KVAC |
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (@load ≧75%) ; EN61000-3-3, GB17743, GB17625.1 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level(surge immunity:Line-Earth:4KV,Line-Line:2KV) |
MTBF |
175Khrs min. MIL-HDBK-217F (25℃) |
Packing |
0.62Kg; 20pcs/13.4Kg/1.11CUFT |
Dimension |
Refer to mechanical specification |