AC
input voltage range |
100 ~ 305VAC 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
AC Inrush Current (Typ.) |
COLD START 50A(twidth=350μs measured at 50% Ipeak)/230VAC; Per NEMA 410 |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
225~260V, 160~190V, 115~140V, 80~100V, 64~79V
Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, re-power on to recover |
Working temperature |
Tcase=-40 ~ +85℃(Please refer to " OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;
IP65 or IP67; GB19510.1, GB19510.14 approved |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2.0KVAC
O/P-FG:1.5KVAC |
EMC EMISSION |
Compliance to EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3; GB17743, GB17625.1 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:6KV,Line-Line:4KV) |
MTBF |
1171.4K hrs min. Telcordia SR-332 (Bellcore) 305Khrs min. MIL-HDBK-217F (25℃) |
Packing |
0.8Kg;16pcs/13.4Kg/0.67CUFT |