AC
input voltage range |
100 ~ 305VAC, 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
AC Inrush Current (Typ.) |
COLD START 60A(twidth=510μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 |
OVER CURRENT |
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
27~34V, 42~49V, 47~54V, 54~63V, 60~67V
Shut down output voltage, re-power on to recover |
Over Temperature |
Shut down output voltage, re-power on to recover |
Working temperature |
Tcase=-40 ~ +90℃(Please refer to " OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;GB19510.14,GB19510.1; IP65 or IP67 approved |
Withstand voltage |
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC |
EMC EMISSION |
Compliance to EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3;GB17625.1,GB17743 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
MTBF |
826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25℃) |
Packing |
1.22Kg; 12pcs / 15.2Kg / 0.72CUFT |