AC
input voltage range |
100 ~ 305VAC 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section) |
AC Inrush Current (Typ.) |
COLD START 65A(twidth=485μs measured at 50% Ipeak)/230VAC; Per NEMA 410 |
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
320~360V, 230~265V, 155~180V, 128~150V, 96~106V, 82~92V
Shut down o/p voltage, re-power on to recover |
Over Temperature |
Shut down o/p voltage, re-power on to recovery |
Working temperature |
Tcase=-40 ~ +90℃(Please refer to " OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;GB19510.1, GB19510.14; IP65 or IP67 approved |
Withstand voltage |
I/P-O/P:3.75KVAC
I/P-FG:2.0KVAC
O/P-FG:1.5KVAC |
EMC EMISSION |
Compliance to EN55015,EN61000-3-2 Class C (@load≧60%) ; EN61000-3-3; GB17743,GB17625.1 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
MTBF |
1098.95K hrs min. Telcordia SR-332 (Bellcore) 308.5Khrs min. MIL-HDBK-217F (25℃) |
Packing |
0.95Kg; 16pcs / 16.0kg / 0.77CUFT |
Dimension |
219*63*35.5 mm (L*W*H) 308.5Khrs min. MIL-HDBK-217F (25℃) |