Features : * AC input 180~264VAC only
* 130% peak load capability
* 110mm slim design
* Built-in active PFC function, compliance to EN61000-3-2
* High efficiency 94% and low power dissipation
* Protections: Short circuit / Overload / Over voltage / Over temperature
* Cooling by free air convection
* Built-in constant current limiting circuit
* Can be installed on DIN rail TS-35/7.5 or 15
* UL 508(industrial control equipment)approved
* EN61000-6-2(EN50082-2) industrial immunity level
* Current sharing up to 3840W(3+1)
* Built-in DC OK relay contact
* 100% full load burn-in test
* 3 years warranty
Model No. : SDR-960
AC input voltage range 180 ~ 264VAC 254 ~ 370VDC
AC inrush current (max.) COLD START 50A / 230VAC
Over Load Protection Normally works within 105% ~ 130% rated output power for more than 3 sec and then shut down o/p voltage with auto-recovery, after 30 seconds if the peak load condition is removed
Constant current limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power on to recover
Over voltage Protection 29~33V, 56~65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Over Temperature Shut down o/p voltage, recovers automatically after temperature goes down
Withstand Voltage I/P-O/P: 3KVAC
I/P-FG: 2KVAC
O/P-FG: 0.5KVAC
O/P-DC OK: 0.5KVAC
Working Temperature -30°C ~ 70°C (refer to output derating curve)
Safety standards UL508, TUV EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved ; (meet EN60204-1)
EMC EMISSION Compliance to EN55032 (CISPR32), EN61204-3 Conduction class B, Radiation class A, EN61000-3-2,-3, EAC TP TC 020, BSMI CNS13438
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020
MTBF 69.8K hrs min. MIL-HDBK-217F (25℃)
Packing 2.47Kg ; 6pcs/15.8Kg/1.55CUFT
Dimension 110*125.2*150mm (W*H*D)
SDR-960 / 960W Single Output Din Rail AC DC power supply
Model No. DC VOLTAGE CURRENT RANGE RATED POWER VOLTAGE TOLERANCE R. & N. Effi.
SDR-960-24 24V 0~40A 960W ±1% 180mV 94%
SDR-960-48 48V 0~20.0A 960W ±1% 250mV 94%
 
Download PDF Here